Athlete Profile
· 29-year-old male
· Elite-level aerobic capacity
· Structured competition preparation phase
· Subject to doping testing (result: negative)
Professional Athlete Performance Progression Report
Testing Dates: 27/05/16 – 13/06/16
Key Improvements:
• VO2peak: 4.15 -> 6.61 L/min (+59%)
• Relative VO2max: 42.8 -> 68.1 ml/kg/min (+59%)
• Peak Power: 330 -> 429 W (+30%)
• Anaerobic Threshold: 28.2 -> 50.4 ml/kg/min (max observed)
• Oxygen Pulse: 27.5 -> 39.1 ml/beat (+42%)
1. Aerobic Capacity (VO₂peak)
Absolute VO₂peak (L/min)
|
Date |
VO₂peak |
|
27/05 |
4.150 |
|
06/06 |
4.947 |
|
10/06 |
5.590 |
|
13/06 |
6.605 |
Change from first to peak test:
+2.455 L/min
+59.1% increase
Relative VO₂max (ml/kg/min)
|
Date |
ml/kg/min |
|
27/05 |
42.8 |
|
06/06 |
53.2 |
|
10/06 |
60.1 |
|
13/06 |
68.1 |
Absolute increase:
+25.3 ml/kg/min
+59.1%
2. Peak Power Output
|
Date |
Max Watts |
|
27/05 |
330 W |
|
06/06 |
345 W |
|
10/06 |
360 W |
|
13/06 |
429 W |
Total increase:
+99 W
+30% improvement in peak workload tolerance
3. Anaerobic Threshold (AT)
AT (ml/kg/min)
|
Date |
AT |
|
27/05 |
28.2 |
|
06/06 |
37.3 |
|
10/06 |
50.4 |
|
13/06 |
45.8 |
Improvement first → best value:
+22.2 ml/kg/min
+78.7% increase in threshold capacity
AT as % of VO₂peak
|
Date |
% |
|
27/05 |
64% |
|
06/06 |
70% |
|
10/06 |
84% |
|
13/06 |
67% |
Peak efficiency observed on 10/06 at 84% of VO₂peak.
4. Oxygen Pulse (Stroke Volume Proxy)
|
Date |
O₂ Pulse (ml/beat) |
|
27/05 |
27.5 |
|
06/06 |
31.9 |
|
10/06 |
34.9 |
|
13/06 |
39.1 |
Increase:
+11.6 ml/beat
+42% increase
Indicates strong central cardiac contribution to performance increase.
5. Peak Heart Rate
|
Date |
HRpeak |
|
27/05 |
151 bpm |
|
06/06 |
155 bpm |
|
10/06 |
160 bpm |
|
13/06 |
169 bpm |
Progressive ability to tolerate higher cardiovascular stress.
6. Ventilatory Response
Peak Ventilation (VE)
|
Date |
VE (L/min) |
|
27/05 |
128.0 |
|
06/06 |
160.5 |
|
10/06 |
178.0 |
|
13/06 |
208.4 |
Increase:
+80.4 L/min
+63% ventilatory capacity expansion
7. Pulmonary Function (Spirometry)
Across all tests:
- FEV1: ~5.14–5.28 L (107–110% predicted)
- FVC: ~6.52–6.84 L (113–118% predicted)
No obstruction. No pulmonary limitation.
SUMMARY OF PERFORMANCE GAINS (FIRST → PEAK TEST)
- VO₂peak: +59%
- Relative VO₂max: +59%
- Peak Power: +30%
- Anaerobic Threshold: +78%
- Oxygen Pulse: +42%
- Peak Ventilation: +63%
Interpretation in Competitive Context
During the monitored micro-cycle:
- Aerobic ceiling expanded substantially.
- Threshold shifted upward.
- Power output at maximal stress increased.
- Cardiac stroke volume proxy improved.
- No pathological cardiac or pulmonary findings.
- Ventilatory efficiency remained within normal limits.
Data supporting the findings of this study are available from the corresponding author on reasonable request.